14 PREMIUM CHEMICAL REMOVAL FILTER INSTALLATION AND USER GUIDE BARRIE ● ONTARIO ● CANADA 705.733.8900 WWW.EXCALIBURWATER.COM System Setup MODEL VARIABLE COMPONENTS AND SPECIFICATIONS Model1 Number Mineral Tank Media Quantity Flow (GPM) Drain Flow Control Shipping Weight Dia X Height (inch) Continuous Peak Flow (GPM) Order # ft3 LBS EWS BTPCS1 9X48 1.0 4.0 6.0 4.2 CLK V3162042 80 Step 1SS: - Press and hold “SET” and ▲ buttons simultaneously for 3 seconds and release. Again press and hold “SET” and ▲ buttons simultaneously for 3 seconds and release. Step 2SS: - Press ▲ or ▼ buttons to select program “P 8”. Press “SET” button to proceed to step 3SS. Step 3SS: - Use ▲ or ▼ buttons to select “99” number of days between regeneration. Note: - For weekly 7 days regeneration specific scheduled regeneration for each day is required. Step 4SS: - Use ▲ or ▼ buttons to switch between immediate regeneration and scheduled regeneration. When “Regen Time” arrow is not displayed then regeneration will occur immediately and when “Regen Time” arrow is displayed the regeneration will occur at scheduled time of day when DP switch closes. EWS BTPCS2 12X52 2.0 7.5 10.0 6.5 CLK V3162065 145 6.0 8.0 5.3 CLK V3162053 100 EWS BTPCS1.5 10X54 1.5