Excalibur Superior Chemical Removal Filter Manual

8 SUPERIOR CHEMICAL REMOVAL FILTER INSTALLATION AND USER GUIDE BARRIE ● ONTARIO ● CANADA 705.733.8900 WWW.EXCALIBURWATER.COM START UP INSTRUCTIONS 1. Turn off the cold main water supply and inlet to hot water tank to the home and open inside cold faucets to relieve any pressure within the plumbing system. 2. Place the system in the desired location. Make sure that the location is level and sturdy enough to support the weight. 3. Place the bypass valve in the up-flow service position. 4. Connect the cold water supply to the inlet of the Soft-tec system. NOTE: The Soft-tec system operates in the UP-flowmode which is opposite of a conventional softener, see piping schematic in manual. 5. Place a bucket under the outlet port or run a line from the outlet port to a drain location. 6. Slowly turn the water back on to the house feeding the Soft-tec system up-flow inlet. Allow the tank to fill with water. Close the supply valve when a steady stream of water comes out of the outlet port. 7. Close the inside faucets. 8. Connect the outlet of the Soft-tec system to the cold-water supply to the house. 9. Slowly open the supply valve to the Soft-tec system. 10. Open the closest cold water faucet downstream from the Soft-tec system to relieve any air from the plumbing system and run until water is clear. 11. Open inlet feed water supply to hot water tank. 12. Open other cold water faucets in the house to release any excess air and run until water is clear. 13. The filter system is now ready for standard water usage providing filtered water to every tap.