Excalibur Zentec™ Hybrid Ozone Capsulate Iron Filter Manual

4 FILTER INSTALLATION AND USER GUIDE BARRIE • ONTARIO • CANADA 705.733.8900 WWW.EXCALIBURWATER.COM 1.5) Ozone Generator 1.5.1) Description Specifications: - Ozone Production: - 0.3 Grams per Hour @ 6 SCFH Concentration: - 0.20 Current Draw: - 0.14 Amperes @120V/60Hz Control Knob (0-100%) Power plug Ground Wire Lug Inlet / Outlet Ozone Generator The compact size ozone generator generates the ozone gas which is transferred to the mineral tank during regeneration. The ozone gas is capsulated in the top of the tank the water travel through the Ozone before getting filtered through the Zentec Media. Ozone Generator must be mounted on Control Valve. Ozone and Air Hose Connections The two hose connections on the generator are inlet and outlet. If one connection is connected to control valve, then other connection will act as inlet for ozone generator. The inlet and outlet connections can be exchanged. No air preparation is needed so the inlet connection of Generator should not be connected to anything. Electrical Connections The relay connection of Ozone Generator must be connected to the PC Board’s relay terminal block. So, that Ozone Generator must be switched on only during the regeneration of filter. Ground lug must be connected to the ground wire. Ground Wire Lug Inlet / Outlet POWER INDICATOR