Excalibur Soft-Tec® Chemical Removal Pre-treatment Filter Manual

6 FILTER INSTALLATION AND USER GUIDE BARRIE ● ONTARIO ● CANADA 705.733.8900 WWW.EXCALIBURWATER.COM Installation Instructions 1) The water heater’s inlet must be at least 10ft away from filter. 2) The unit must be located in a room temperature above 33° F. 3) If vacuum occurrence is expected then the vacuum breaker must be installed at the inlet of the filter. 4) The unit must not be exposed to direct sunlight. Ultraviolet rays can damage the system 5) The primer, solder or solder flux must not get on the O-rings while installation. 6) After soldering the lines must be cooled before installing the O-Rings, nuts and caps. 7) If the electrical system is grounded to the plumbing, then a copper strap must be connected between inlet and outlet as shown in figure. 8) The plumbing must be done by following the local plumbing codes. 9) If heavy dirt and debris has been tested or expected in future, then 20-micron sediment filter should be installed in pre-treatment. 10) If booster pump is required always install the pump upstream of the system. SPECIFICATIONS Model Number1 Mineral Tank Media ft3 (Liters) Flow GPM (LPS) Space Required Shipping Weight Dia X Height Continuous Peak LxWxH LBS EWS POUPCS075 8X44 0.75 (21.2) 5.0 (0.32) 8.0 (0.50) 14x9x48 35 EWS POUSBCS075 8x44 0.75 (21.2) 5.0 (0.32) 8.0 (0.50) 14x9x48 37 1: - EWS POUPCS075 is Premium Model and EWS POUSBCS075 is Superior Model