Excalibur Filtermax™ Tannin Filter Manual

13 FILTER INSTALLATION AND USER GUIDE BARRIE ● ONTARIO ● CANADA 705.733.8900 WWW.EXCALIBURWATER.COM 2.8) System Setup Step 1SS: - Press and hold “SET” and ▲ buttons simultaneously for 3 seconds and release. Again press and hold “SET” and ▲ buttons simultaneously for 3 seconds and release. Step 2SS: - Press ▲ or ▼ buttons to select program “P 1”. Press “SET” button to proceed to step 3SS. Step 3SS: - Select the duration for fill cycle using ▲ or ▼ buttons. Refer to the specifications table. Press “SET” button to proceed to step 4SS. Step 4SS: - Use ▲ or ▼ buttons to select “99” number of days between regeneration. Note: - For weekly 7 days regeneration specific scheduled regeneration for each day is required. Step 5SS: - Use ▲ or ▼ buttons to switch between immediate regeneration and scheduled regeneration. When “Regen Time” arrow is not displayed then regeneration will occur immediately and when “Regen Time” arrow is displayed the regeneration will occur at scheduled time of day when DP switch closes.

RkJQdWJsaXNoZXIy NTc4ODc=