2 FILTER INSTALLATION AND USER GUIDE BARRIE ● ONTARIO ● CANADA 705.733.8900 WWW.EXCALIBURWATER.COM INSTALLATION Pre-installation instructions The cycle times, sequence of cycles and days between regeneration are preset by Excalibur Water Systems. WATER TEST Hardness _________________gpg Iron _________________ppm Ph _________________number Nitrates _________________ppm Manganese _________________ppm Sulphur _________________yes/no Total Dissolved Solids _________________ General Installation and Service Warnings • The filter is designed so that it can be installed easily with minor plumbing changes on previous plumbing. • The piping must be clamped properly and the weight of the plumbing must not be on the filter. • Do not use any kind of lubricant including silicone. A silicone based lubricant can be only used on black O-Rings but not necessary. • Do not use pipe dope or other sealant on plastic nuts and caps. Teflon tape must be used only on NPT threads. • The nuts and caps can be fastened and unfastened by hand or the plastic service wrench. Do not use pipe wrench to tighten the caps and nuts. Site Requirements • Water Pressure: - 40-110 psi • Water Temperature: - 40-110°F (4.4-43°C) • Electrical- 115/120 V, 60Hz Uninterrupted Outlet • Current required is 0.5 Amperes with plug-in transformer (dry locations only). • The tank should be on a firm level surface