Excalibur Premium Series Water Softener Manual

29 SOFTENER INSTALLATION AND USER GUIDE BARRIE • ONTARIO • CANADA 705.733.8900 WWW.EXCALIBURWATER.COM 8) QUICK REFERENCE GUIDE Manual Regeneration Immediate Regeneration: - Press and hold “REGEN” button for more than 3 seconds. Press “REGEN” button to advance the unit to next cycle in regeneration. Delayed Regeneration: - Press and release “REGEN” button once the “REGEN TODAY” will be flashing on screen. Now the regeneration will occur tonight at preset time. The delayed regeneration can be cancelled by pressing “REGEN” button again. This error screen and error number will toggle. Contact Service Technician or Excalibur to report the error code. The bypass valve handles must be turned towards the center as shown above The bypass valve handle must be in the direction of flow and engraved arrows on control valve. Set Time of Day • Press “SET CLOCK” button. • Hours will flash press up and down buttons to adjust hours to current hour of day. Then press “NEXT” button. • By pressing up and down buttons adjust minutes. Then press “NEXT” button. • The time is set and the valve display will return to normal display.