Excalibur Value Series Water Softener Manual

12 SOFTENER INSTALLATION AND USER GUIDE BARRIE ● ONTARIO ● CANADA 705.733.8900 WWW.EXCALIBURWATER.COM 3) MODEL VARIABLE COMPONENTS AND SPECIFICATIONS 3.1) Flow Controls and Injectors Model Number Mineral Tank Brine Tank Injector Drain Flow Control Dia X Height (Inch) (Inch) Color Order # Flow GPM Order # EWS S25BF 8x44 14x14x34 (Length x Width x Height) Violet CLK V30101C 1.7 CLK V3162017 EWS S30BF 9x48 Red CLK V30101D 2.2 CLK V3162022 EWS S40BF 10x54 White CLK V30101E 2.7 CLK V3162027 EWS S50BF 10x54 White CLK V30101E 2.7 CLK V3162027 EWS S60BF 12x52 18x33 (Dia x Height) Blue CLK V30101F 3.2 CLK V3162032 3.2) Specifications * Excalibur Softeners are factory programmed to 10lbs/ft3 default settings Model Number Mineral Tank Resin Quantity Grains Capacity Lbs Salt Setting Flow (GPM) Shipping Weight Dia X Height ft 3 6 lbs Salt/ft3 10 lbs Salt/ft3 15 lbs Salt/ft3 Continuous Peak LBS EWS S25BF 8X44 0.83 17,000 5 22,000 8.5 25,000 13 4.2 6.6 70 EWS S30BF 9X48 1.00 20,000 6 27,000 10 30,000 15 5.0 8.0 84 EWS S40BF 10X54 1.33 27,000 8 36,000 13 40,000 20 6.7 10.7 106 EWS S50BF 10X54 1.67 33,000 10 45,000 17 50,000 25 8.4 13.4 124 EWS S60BF 12X52 2.00 40,000 12 54,000 20 60,000 30 10.0 16.0 171 Step 8S – Select “dn” for downflow brine cycle using ▲ or ▼. Press NEXT to go to Step 9S. Press REGEN to return to previous step. Step 9S – Set “NORMAL” for the regeneration time. Press NEXT to exit Softener System Setup or Press REGEN to return to previous step. EXIT SOFTENER SYSTEM SETUP

RkJQdWJsaXNoZXIy NTc4ODc=