Excalibur Zentec™ Hybrid Air Capsulate Iron Filter Manual

26 FILTER INSTALLATION AND USER GUIDE BARRIE • ONTARIO • CANADA 705.733.8900 WWW.EXCALIBURWATER.COM Problem Possible Cause Solution 7. Control valve does not regenerate automatically but does when the REGEN button is depressed and held a. Incorrect programming a. Check for programming error b. Defective PC Board b. Replace PC Board 8. Unfiltered water is being delivered a. Bypass valve is in bypass position or faulty a. Fully turn handles of bypass valve or replace if faulty b. Media is exhausted due to high water usage b. Check program settings or diagnostics for abnormal water usage d. Water quality fluctuation d. Test water and adjust program values accordingly f. Control fails to draw in air f. Refer to Trouble Shooting Guide number 9 h. Damaged seal/stack assembly h. Replace seal/stack assembly i. Control valve body type and piston type mix matched i. Verify proper control valve body type and piston type match j. Fouled media bed j. Replace media bed 9. Control valve fails to draw in Air a. Injector is plugged a. Remove injector and clean or replace b. Faulty regenerant piston b. Replace regenerant piston d. Drain line restriction or debris cause excess back pressure d. Inspect drain line and clean to correct restriction e. Drain line too long or too high e. Shorten length and or height f. Low water pressure f. Check incoming water pressure – water pressure must remain at minimum of 25 psi 10. Water running to drain a. Power outage during regeneration a. Upon power being restored control will finish the remaining regeneration time. Reset time of day. b. Damaged seal / stack assembly b. Replace seal / stack assembly c. Piston assembly failure c. Replace piston assembly d. Drive cap assembly not tightened in properly d. Re-tighten the drive cap assembly 11. E1, Err – 1001, Err – 101 = Control unable to sense motor movement a. Motor not inserted full to engage pinion, motor wires broken or disconnected a. Disconnect power, make sure motor is fully engaged, check for broken wires, make sure two pin connector on motor is connected to the two pin connection on the PC Board labeled MOTOR. Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect. b. PC Board not properly snapped into drive bracket b. Properly snap PC Board into drive bracket and then Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect. c. Missing reduction gears c. Replace missing gears

RkJQdWJsaXNoZXIy NTc4ODc=