Excalibur Zentec™ Hybrid Air Capsulate Iron Filter Manual

29 FILTER INSTALLATION AND USER GUIDE BARRIE • ONTARIO • CANADA 705.733.8900 WWW.EXCALIBURWATER.COM 5) QUICK REFERENCE GUIDE Regeneration To Set Time of Day Immediate Regeneration: - Press and hold “REGEN” button for more than 3 seconds. Press “REGEN” button to advance the unit to next cycle in regeneration. Delayed Regeneration: - Press and release “REGEN” button once the “REGEN TODAY” will be flashing on screen. Now the regeneration will occur tonight at preset time. The delayed regeneration can be cancelled by pressing “REGEN” button again. This error screen and error number will toggle. Refer Page#28 or contact Service Technician or Excalibur and report the error code. To shut off supply to the Unit the bypass valve handle must be in direction given above. The inlet handle arrow must be in the direction of unit and outlet handle must direct away from the unit as given above. • Push NEXT until time of day screen is displayed. • Press and hold ▼ until the hour flashes once. Press ▲ or ▼ until the correct hour is displayed. Then press NEXT. • The minutes will flash. Press ▲ or ▼ until the correct minute is displayed. • Press NEXT to return to the User Displays.

RkJQdWJsaXNoZXIy NTc4ODc=