Excalibur Premium Reverse Osmosis System Manual

10 REVERSE OSMOSIS INSTALLATION AND USER GUIDE BARRIE ● ONTARIO ● CANADA 705.733.8900 WWW.EXCALIBURWATER.COM Holding Tank • Check the Reverse Osmosis tank air pre-charge pressure. Make sure it is between 5 to 7 psig. • Pull the cap/plug off the top of the Reverse Osmosis tank where the Reverse Osmosis Tank Shut-Off should go. • Wrap Teflon tape three times around the ¼" male outlet thread. Wrap in the direction of the threads. The tape will act as a thread sealant. Screw on the Reverse Osmosis Holding Tank Shut-Off Valve. • Locate the 3/8" Reverse Osmosis Tubing. Firmly press one end into the Reverse Osmosis Holding Tank Shut-Off Valve and the other end into the tee. The fittings will grab the Reverse Osmosis tubing and seal it in place. Make sure the Reverse Osmosis tubing is pressed all the way in to create a pressure tight connection. Figure: - Angle Valve Adapter