Excalibur Smart Purifier™ Reverse Osmosis System Manual

13 Operation The RO system is equipped with an LED display.When connecting the power supply,the machine buzzes once and goes into rinse mode. 1. Rinse 1 )Auto Rinse: Every time the power supply is connected the RO systemwill flush automatically. If the system is not used for more than 72 hours, the systemwill flush automatically. 2) When flushing,booster pump,inlet water solenoid valve and drain water are all in working mode,flushing last for 15 seconds,this will be indicated on the front panel. 3) If you press the"Select"button once,the machine will flush for 30 seconds. 2. Purify Turn on the water tap and start filtering,the inlet water solenoid valve and booster pump start working,this is indicated on the front panel. 3. Leak When leaking,the"Leak"indicator on the front panel will turn red and a 6 seconds alarm goes off.After solving the problem,reconnect the power and restart the machine. 4. Fault When continuously filtering or rinsing for1 hour,the fault light turn red meanwhile buzzing for 6 seconds until solve the problems to connect the power again. 5. Cartridge Life Filter life time is indicated on the front panel.Over time and usage the bars will lower.When the last bar is arrived,a 10 second alarm goes off.After that,for 3 more times,every half an hour an alarm goes off. 6. Replace Cartridge Press "Reset" button for 3 seconds until you hear a sound.You are in replacement mode now.To switch between cartridges,push "Select" once. Select the cartridge to be changed and press "Reset" button for 3 seconds until you hear a sound.