Excalibur Value Reverse Osmosis System Manual

NOTE: THIS STEP FOR REMOTE LOCATIONS ONLY STEP SEVEN – INSTALL RO SYSTEM & DRAIN Route remote drain point and conRgure air gap. Running drain tubing to an existing drain is also an option but may require longer tube lengths. Suitable drains include laundry tubs, Soor drains or sumps. Check local plumbing codes. Note: To prevent water from backing up into system, be sure to allow air gap between drain point and end of hose. 1 Determine if tubing is long enough to reach drain. If yes, insert restrictor in end of tubing and insert this end into drain port on membrane Rlter. If no, replace white tubing with tubing of adequate length and insert restrictor into end of tubing. Insert this end of tubing into drain port on membrane Rlter. 2 Run tubing to drain point securing at end with bracket (not supplied). Ensure 1-1/2” air gap is between drain and end of tube. 3 Install shroud with short side to the back by sliding shroud over manifold until it is snug. Note: Faucet will not have tubing attached to air gap barbs in faucet body for remote installation. 2” Minimum Restrictor Tube to Drain Point Tube to Faucet Tube to Tank 8