Excalibur Soft-Tec® Scale Control System Manual

14 SCALE CONTROL CONDITIONER INSTALLATION AND USER GUIDE BARRIE ● ONTARIO ● CANADA 705.733.8900 WWW.EXCALIBURWATER.COM 7) TROUBLESHOOTING PROCEDURES Problem Possible Cause Solution 1. Untreated water is being delivered a. Bypass valve is open or faulty a. Fully close bypass valve or replace b. Water quality fluctuation b. Test water and adjust pre-treatment if exists c. Damaged seal c. Replace seal d. Fouled media bed d. Replace media bed 2. Water leaking at the top of the tank around the head a. Loose tank head a. Loosen and take out the inlet and outlet plumbing connections and then turn the head by holding the tank. (Just snug the head over the tank do not overtighten) 3. Water pressure decreased a. Plugged sediment filter (if exists) a. Replace the cartridge filter b. Removal of scale plugged the faucet aerators (Only within 90 days of installation) b. Remove the aerator, open the faucet and clean the aerator. c. Tank is not straight vertical c. Level the tank vertically straight d. Pre-Treatment filters plugged d. Regenerate or replace the faulty pretreatment filters. 4. Leaking bypass valve a. Faulty O-ring a. Replace or lubricate the O-rings b. Loose bypass valve plastic nuts b. Fasten the connection nuts with hands. (Never use pipe wrench to fasten or unfasten)