7 FILTER INSTALLATION AND USER GUIDE BARRIE • ONTARIO • CANADA 705.733.8900 WWW.EXCALIBURWATER.COM Start Up Instructions • Keep the bypass valve in bypass operation by moving both the handles into the center direction of the bypass valve. Now the unfiltered water is being supplied. Open the faucet downstream of the filter until water comes clear out of it. The initial water can be dirty because of installation debris. Now inspect the leaks in plumbing. • Press and hold the “REGEN” button down for 5 seconds to start manual regeneration. The drive motor will start the backwash cycle and countdown time begins. Turn the inlet bypass valve handles halfway into the direction of service operation. Once the steady water flows out of drain then fully open the bypass valve into the direction of service operation. • Once the water coming from the drain becomes clear, press REGEN button to advance the regeneration to draw (brine) cycle. Allow this process for 5 minutes. The system will draw air into the tank and water will also come out of the drain line. • Press the “REGEN” button again to end the regeneration cycle. Open the faucet downstream of the filter check if the water is coming clear.